Confined Space Ventilation Ducting

Filter

Confined space ventilation ducts are designed for use with confined space fans for providing fresh air supply and ventilating hazardous gases & fumes from basements, manholes and...Read more

ALLEGRO SAFETY -

Standard Ductings

Allegro standard ducting have lightweight and retractable design, intended for maximum air handling capabilities and are built for dual direction flow with minimum friction loss. They feature vinyl and polyester materials with PVC covering which make them suitable for use in rough and harsh climatic conditions. These ducts further feature non-collapsible design and a yellow with dark climate strip for perceivability at work and also meet ASTM 227 specifications. Choose from a broad range of these standard ducting, available in 760 and 791 CFM options.

StyleModelLengthDiameterConstructionColorPrice (ex. VAT)
A9500-066 ft.8"-Black, Yellow€70.74
A9550-1515 ft.12"-Yellow€220.50
A9700-1515 ft.26"Vinyl and PolyesterBlack, Yellow€488.32
A9600-1515 ft.16"-Yellow, Black€301.35
A9500-1515 ft.8"-Black, Yellow€133.22
A9650-1515 ft.20"-Yellow€362.91
A9600-2525 ft.16"-Yellow, Black€447.43
A9500-2525 ft.8"-Black, Yellow€166.29
A9550-2525 ft.12"-Yellow€301.35
A9650-2525 ft.20"-Yellow€541.14
A9700-2525 ft.26"Vinyl and PolyesterBlack, Yellow€708.82
AIR SYSTEMS INTERNATIONAL -

Standard and Conductive Ductings, Hazardous Location

StyleModelLengthDiameterColorPrice (ex. VAT)
ASVH-CND866 ft.8"Black€74.94
ASVHCND121515 ft.12"Black€243.56
BSVH-CND81515 ft.8"Black€127.40
CSVH-CND82525 ft.8"Black€187.35
ASVHCND122525 ft.12"Black€296.02
AIR SYSTEMS INTERNATIONAL -

Standard and Conductive Ductings, Non-Hazardous Location

StyleModelLengthDiameterConstructionColorPrice (ex. VAT)
ASVH-33 ft.8"Vinyl and PolyesterYellow€37.47
ASVH-66 ft.8"-Yellow€48.71
ASVH-506 ft.8"PVCYellow-
RFQ
BSVH-121515 ft.12"-Yellow€138.64
CSVH-1515 ft.8"-Yellow€89.93
DSVH-2525 ft.8"-Yellow€119.91
BSVH-122525 ft.12"-Yellow€198.59
AIR SYSTEMS INTERNATIONAL -

Lay Flat Disposable Ductings

StyleModelDiameterPrice (ex. VAT)
ASVH-LF8C8"€975.10
BSVH-LF88"€201.76
BSVH-LF1212"€306.68
BSVH-LF1616"€464.06
AMERIC -

Ventilation Ducts, PVC, Vinyl Coated Polyester Construction

Americ ventilation ducts direct fumes & foul air outside and draws fresh air into enclosed spaces. They feature PVC, vinyl coated polyester construction to withstand UV-radiation, humidity & extreme environmental conditions and can easily connect to ventilator fans or blower lips for negative or positive airflow. Further, these UL-listed ducts have easy retractable Schafer duct hoses to handle large volumes of air at low pressures and can collapse into the conveniently attached carrying bags. They are integrated with quick connect couplers, reducing media spillage and are available in lengths of 15 & 25 inches.
Raptor Supplies also offers Americ Disposable Ventilation Duct that can be cut in the lengths as required.

StyleModelLengthDiameterConstructionPrice (ex. VAT)
AGAM-DS121515ft.12"PVC Vinyl Coated Polyester€113.35
AGAM-DS081515ft.8"PVC Vinyl Coated Polyester€94.17
BGAM-DS0825CB25ft.8"PVC Vinyl Coated Polyester€178.29
AGAM-DS082525ft.8"PVC Vinyl Coated Polyester€140.21
AGAM-DS122525ft.12"PVC Vinyl Coated Polyester€239.93
BGAM-DS1225CB25ft.12"PVC Vinyl Coated Polyester€243.31
AGAM-DS202525ft.20"PVC Vinyl Coated Polyester€403.66
StyleModelLengthDiameterConstructionColorPrice (ex. VAT)
AGAM-DDISP500FR500ft.12"PolyethyleneClear€423.24
AGAM-DDISP500500ft.12"PolyethyleneClear€318.37
ECKO -

Ventilation Ducts

StyleModelLengthDiameterConstructionColorPrice (ex. VAT)
AFDT-21624046BR15ft.8.5"2-Ply Flame Retardant Polyvinyl with Polyester Reinforcement, End Finish: Cinch Belt x RingYellow€182.57
BFDT-1215CBB15ft.12"Antistatic-2-Ply Flame Retard. PVC on Polyester Fabric-End Finish, Cinch Belt x Cinch BeltBlack€624.55
AFDT-30534005BB16ft.12"2-Ply Flame Retardant Polyvinyl with Polyester Reinforcement, End Finish: Cinch Belt x Cinch BeltYellow€285.97
AFDT-21624076BR25ft.8.5"2-Ply Flame Retardant Polyvinyl with Polyester Reinforcement, End Finish: Cinch Belt x RingYellow€286.21
BFDT-1225CBB25ft.12"Antistatic-2-Ply Flame Retard. PVC on Polyester Fabric-End Finish, Cinch Belt x Cinch BeltBlack€1,012.25
BFDT-1625CBR25ft.16"Antistatic-2-Ply Flame Retard. PVC on Polyester Fabric-End Finish, Cinch Belt x RingBlack€1,208.81
AFDT-1625BR25ft.16"2-Ply Flame Retardant Polyvinyl with Polyester Reinforcement, End Finish, Cinch Belt x RingYellow€548.91
ALLEGRO SAFETY -

Statically Conductive EX Ductings

StyleModelDesignDiameterItemLengthTemp. RangePrice (ex. VAT)
A9550-25AEX-12"Statically Conductive Duct25 ft.-€736.59
RFQ
A9600-15AEX-16"Statically Conductive Duct15 ft.-€1,056.10
RFQ
A9600-25AEX-16"Statically Conductive Duct25 ft.-€1,077.92
RFQ
A9550-15AEX-12"Statically Conductive Duct15 ft.-€426.61
RFQ
A9500-15AEX-8"Static Conductive Duct15 ft.Upto 250° F€196.84
A9500-25AEX-8"Static Conductive Duct25 ft.Upto 250° F€275.40
A9500-25EXNon Collapsible8"Statically Conductive Duct25 ft.-65° to 250° F€274.71
A9500-15EXNon Collapsible8"Statically Conductive Duct15 ft.-65° to 250° F€197.53
B9650-25EXRetractable, Non Collapsible20"Statically Conductive Duct25 ft.-65° to 250° F€1,129.14
A9550-15EXRetractable, Non Collapsible12"Statically Conductive Duct15 ft.Upto 50° F€407.93
A9550-25EXRetractable, Non Collapsible12"Statically Conductive Duct25 ft.Upto 250° F€682.63
A9600-25EXRetractable, Non Collapsible16"Statically Conductive Duct25 ft.-65° to 250° F€936.21
A9600-15EXRetractable, Non Collapsible16"Statically Conductive Duct15 ft.-65° to 250° F€568.71
A9650-15EXRetractable, Non Collapsible20"Statically Conductive Duct15 ft.-65° to 250° F€688.14
RAMFAN -

Pressure Duct

StyleModelPrice (ex. VAT)
AFDT-185MSR€193.54
RFQ
BFDT-1810MSR€333.31
RFQ
RAMFAN -

Standard Duct

StyleModelPrice (ex. VAT)
AFDT-1625BR€272.38
RFQ
AFDT-30534005BB€184.58
RFQ
AFDT-30534010BB€315.39
RFQ
AFDT-1615BR€180.10
RFQ
AFDT-21624046BR€121.86
RFQ
AFDT-21624076BR€172.03
RFQ
RAMFAN -

Quick Couple Long Canister

StyleModelPrice (ex. VAT)
AED7004CL/DS€298.37
RFQ
BEF7004CL/DS€817.15
RFQ
RAMFAN -

Disposable Duct

StyleModelPrice (ex. VAT)
AFDT-12DISP100€79.74
RFQ
AFDT-16DISP100€125.44
RFQ
RAMFAN -

Quick Couple Canister

StyleModelPrice (ex. VAT)
AED7004CL€197.12
RFQ
AED7004CS€179.20
RFQ
BEF7004CL€833.28
RFQ
BEF7004CS€622.72
RFQ
ALLEGRO SAFETY -

Ventilation Ducts

StyleModelDiameterLengthMaterial Of ConstructionPrice (ex. VAT)
A9500-25A8"25 ft.Vinyl, Polyester€178.93
A9500-15A8"-Vinyl, Polyester€154.35
A9600-25A16"25 ft.Vinyl, Polyester material with PVC Coating€517.72
RFQ
A9600-15A16"15 ft.Vinyl, Polyester€324.55
RFQ
RAMFAN -

Reinforced Duct

StyleModelPrice (ex. VAT)
AFDT-1215CBB€369.15
RFQ
AFDT-1615CBR€417.54
RFQ
AFDT-0825CR€166.66
RFQ
AFDT-1225CBB€604.80
RFQ
AFDT-1625CBR€710.53
RFQ
BFDT-081207BB€202.50
RFQ
ECKO -

Vent Duct, 12 Inch Diameter, 33 Feet Length, Yellow

ModelItemPrice (ex. VAT)
FDT-30534010BBAF4EJZ€495.39
RAMFAN -

Unreinforced Layflat Duct, 25 Feet Length

ModelItemPrice (ex. VAT)
FDT-1625SMECL6VQZ€253.57
See Details

Confined Space Ventilation Ducting

Ventilation ducts are designed for use with confined space fans for providing fresh air supply and ventilating hazardous gases & fumes from basements, manholes and chemical processing plants. Raptor Supplies offers a wide array of Allegro, Ecko, Americ, Ramfan and Air Systems International blower exhaust ducts featuring a flexible design for ensuring quick installation in tough-to-reach spaces. Allegro ventilation ducts feature a statically conductive design for discharging the static build-up and preventing accidental sparks in hazardous locations, and a neoprene coating for withstanding temperatures up to 250 degrees F. Ventilation ducts from Air Systems International are made of polyethylene / vinyl for maintaining structural rigidity and also facilitate ease-of-storage & maximum job-site portability. Choose from a wide range of these ducts available in diameters ranging from 8 to 26 inches.

Frequently Asked Questions

How long are these ducting units?

They are available in sizes ranging from 6 to 825 ft.

When does confined space ventilation matter?

Ventilation in confined spaces is always important. According to OSHA's confined space standard (1910.146 Permit Required Confined Spaces), no workers are permitted to enter a space if a gas detector detects an atmospheric hazard. Employees are also not permitted to enter a space until forced air ventilation has been used to eliminate atmospheric hazards and this ventilation must continue until all employees have left the workspace.

Are these ducts ideal for use in extreme environmental conditions?

Americ ventilation ducts are made of PVC, vinyl coated polyester and can withstand UV radiation, humidity and extreme environmental conditions. They can also be easily connected to ventilator fans or blower lips for negative or positive airflow.

How do I clean maintain confined space ventilation ducting?

  • Perform visual inspections regularly to check for damage, wear, or blockages.
  • Remove any accumulated debris, dust, or obstructions inside the ducting.
  • Mix water with a mild ducting cleaner or detergent for a suitable cleaning solution.
  • Use a soft brush or cloth to apply the cleaning solution to the interior surface of the ducting.
  • Gently scrub the interior surface to remove dirt, grease or residues without causing damage.
  • Thoroughly rinse the ducting with clean water to remove the cleaning solution and debris.
  • Allow the ducting to air dry completely to prevent moisture buildup.
  • Check seals, joints, and connections for wear or damage, and replace them as needed.
  • Store the cleaned and dried ducting in a clean, dry area away from potential damage or contamination.

How to install confined space ventilation ducting?

  • Prepare the work area by clearing obstacles and debris.
  • Measure the length and width of the installation area and plan the ducting route.
  • Gather all the necessary equipment for installation.
  • Connect the sections of ducting using appropriate connectors and clamps.
  • Position the ducting along the planned route and secure it with straps or hangers.
  • Install the inlet and outlet components, such as grilles or diffusers, ensuring proper alignment.
  • Seal the joints and connections using duct tape or other sealing methods.
  • Test the system for proper airflow, functionality, and potential leaks or obstructions.

What are the safety precautions to consider while using confined space ventilation ducts?

It is important to ensure that the ducting is properly secured and does not obstruct pathways or create trip hazards. Regular inspection and maintenance should be conducted to identify any damage or wear and replace any worn-out components.

We are here to help!

Looking for a part not listed here?