RANCO Single Pressure Controls

Designed for use with HVAC compressors to avoid loss of refrigerant. Feature a DPST / SPST / SPDT switch and can control pressures ranging from 0 to 450 psi

Filter

RANCO -

Low / High Pressure Controls, SPST, NEMA 1 Enclosure

Ranco O Series pressure controls are suitable for protecting compressors from losing refrigerants or from excessive system pressure, which may further damage the condenser fans in the HVAC systems. These single-pressure controls have a heavy-duty plated steel frame with a non-conductive plastic cover for added strength. They feature a compact design for use in tight spaces, an auto reset button on manual controls for quick setting and easy-to-read low- / high-pressure scale plates. They also come integrated with laser welded bellows for an extended life service and screw terminals for easy wiring connection. Choose from an array of these pressure controls available in 5 to 35, 10 to 40 and 40 to 150 psi differential pressure options.

StyleModelConnectionDifferential PressureFunctionRangeTypePrice (ex. VAT)
AO10-1402Copper Capillary withFlare Nut5 to 35 PSITo Protect the Compressor Loss of Refrigerant in Commercial Refrigeration and Air Conditioning Systems(12") to 50 PSILow Pressure€108.73
AO10-1483Copper Capillary withFlare Nut10 to 40 PSITo Protect the Compressor Loss of Refrigerant in Commercial Refrigeration and Air Conditioning Systems(10") to 100 PSILow Pressure€128.80
AO10-2054Copper Capillary with Flare Nut40 to 150 PSITo Protect the Compressor from Excessive System Pressure which Could be Caused by Condenser Fan Failure100 to 400 psiHigh Pressure€132.11
BO10-1401Male Flare5 to 35 PSITo Protect the Compressor Loss of Refrigerant in Commercial Refrigeration and Air Conditioning Systems(12") to 50 PSILow Pressure€90.84
RANCO -

Single Pressure Controls

StyleModelConnectionDifferential PressureFunctionMountingRangeSwitch ActionSwitch TypeTypePrice (ex. VAT)
AO11-1711Copper Capillary withFlare Nut40 to 150 PSITo Protect the Compressor from Excessive System Pressure which Could be Caused by Condenser Fan FailureUniversal150 to 450 psiOpens On High PressureSPSTHigh Pressure€90.77
AO16-108Copper Capillary withFlare Nut40 to 150 PSITo Protect the Compressor from Excessive System Pressure which Could be Caused by Condenser Fan FailureUniversal100 to 400 psiOpens on High/Low PressureSPDTHigh Pressure€134.54
AO20-7006Copper Capillary withFlare Nut40 to 150 PSITo Protect the Compressor from Excessive System Pressure which Could be Caused by Condenser Fan FailureUniversal100 to 400 psiOpens On Low PressureDPSTHigh Pressure€134.05
Bo16-624Flare Nut5 to 38 PSILow Pressure ControlBracket or Surface Mount(12") to 80 PSIOpens On Low PressureSPSTLow Pressure€103.87