Vacuum breakers are used in the chemical and pharmaceutical industries to prevent vacuum formation in a piping system. They allow air to enter the system when the pressure drops. Raptor...Read more

WATTS -

Dual Check Backflow Preventers

StyleModelItemPrice
A3/8 SD3-MNBackflow Preventer€462.53
B1X1 LF7R10-U2Backflow Preventer€167.18
A3/8 SD3-FNBackflow Preventer€516.72
C3/4 9DM2-PRESSDual Check Valve€165.72
WATTS -

LF008PCQT Series Vacuum Breakers

StyleModelInlet SizeMax. Temp.Max. Working PressureMin. Temp.Outlet SizeThread TypePrice
ALF008-PC-QT-SC 11"180° F150 psi33° F1"NPT€2,896.14
RFQ
BLF008PCQT 11"180° F150 psi33° F1"NPT€1,093.13
RFQ
CLF008PCQT 1/21/2"180° F150 psi33° F1/2"NPT€601.94
DLF008PCQT-L 1/21/2"180 Degree F10.3 Bar33 Degree F1/2"FPT€840.39
ALF008PCQT-SC 1/21/2"180° F150 psi33° F1/2"NPT€1,713.92
DLF008PCQT 3/43/4"180 Degree F10.3 Bar33 Degree F3/4"NPT€990.23
RFQ
ELF008-PC-QT-SC 3/43/4"180 Degree F10.3 Bar33 Degree F3/4"NPT€2,542.57
RFQ
DLF008PCQT-L 3/43/4"180 Degree F10.3 Bar33 Degree F3/4"FPT€1,060.65
RFQ
ALF008PCQT-SC 3/83/8"180° F150 psi33° F3/8"NPT€1,713.92
BLF008PCQT 3/83/8"180° F150 psi33° F3/8"NPT€783.08
DLF008PCQT-L 3/83/8"180 Degree F10.3 Bar33 Degree F3/8"FPT€735.41
ZURN -

Vacuum Breaker 3/4 Inch Fnpt x Fnpt

ModelItemPrice
34-35XLAB6WKN€70.07
CASH ACME -

Vacuum Breaker, 3/4 Inch Size, GHT Connection, Brass, 1 5/16 Inch Width

ModelItemPrice
17148-0000LFCJ3RZK€9.27
ZURN -

Atmospheric Vacuum Breaker With Vertical Inlet And outlet, 1 Inch Size

ModelItemPrice
14-35XLVCHCV8MVR€66.30
ZURN -

Vacuum Breaker 3/4 Inch Ght

ModelItemPrice
BFP-8FAB6WKV€28.57
WATTS -

Atmospheric Vacuum Breaker 3/8 Inch Fnpt

ModelItemPrice
3/8 LFN388-CAG6RHN€321.53
ZURN -

Vacuum Breaker 1 Inch Fnpt x Fnpt 125 Psi

ModelItemPrice
1-35XLAB6WKP€86.78
ZURN -

Vacuum Breaker 1/2 Inch Fnpt x Fnpt

ModelItemPrice
12-35XLAB6WKM€72.86
ZURN -

Vacuum Breaker 1-1/4 Inch Fnpt x Fnpt

ModelItemPrice
114-35XLAB6WKQ€186.19
ZURN -

Vacuum Breaker 1-1/2 Inch Fnpt x Fnpt

ModelItemPrice
112-35XLAB6WKR€214.13
ZURN -

Vacuum Breaker 2 Inch Fnpt x Fnpt 125 Psi

ModelItemPrice
2-35XLAB6WKT€379.42
ZURN -

Vacuum Breaker 3/4 Inch Ght

ModelItemPrice
BFP-9AB6WKU€12.37
HAYWARD -

Vacuum Breaker 3/4 Inch Fnpt Pvc 150 Psi

ModelItemPrice
VB107X15AC8MAN€297.07
BELL & GOSSETT -

Vacuum Breaker 3/4 Inch Mnpt Brass 150 Psi

ModelItemPrice
62AD8ZRA€179.76
APPROVED VENDOR -

Vacuum Breaker 3/4 Inch Fip 125 Psi

ModelItemPrice
6AJZ3AE7TZX€8.42
SHARKBITE -

Vacuum Breaker 3/4 Inch Ght Brass 2 Inch Height

ModelItemPrice
19600-0000LFAG2LLG€19.40
WATTS -

Anti-Siphon Vacuum Breaker Backflow Preventer, 1/2 Inch Size, Brass

ModelItemPrice
288AC-Z32 1/2BZ3ZWH€152.61
See Details
GUARDIAN EQUIPMENT -

Vacuum Breaker, for L110 In-Line Vacuum Breaker

ModelItemPrice
VBCV7AZC€220.39
See Details
VULCAN HART -

Compartment, Vacuum Breaker

ModelItemPrice
00-856658-00001AP4TKU€105.67
See Details
VULCAN HART -

Vacuum Breaker Kit

ModelItemPrice
00-857015-00001AP4TNE-
RFQ

Vacuum Breakers

Vacuum breakers are designed to prevent back-siphonage of water due to the generation of vacuum in water drainage systems. Raptor Supplies offers a wide range of vacuum breakers from brands like Apollo, Watts, Hayward, Wilkins, Morse, Plast-O-Matic, Sharkbite and Chicago Faucets. Apollo 38-100, 38-200, 38-500 and 38LF-100 Series vacuum breakers are ideal for a maximum pressure of 150 PSI and are available in 1/4 to 2 inch pipe sizes. The brand's 38-100 Series vacuum breakers prevent backflow of polluted water in portable water supply by breaking the vacuum generated during drainage of water. These ASSE 1001 certified breakers feature a heat-resistant silicone seat disc and a check valve with an air inlet. Watts ANSI, ASSE and NSF compliant vacuum breakers also have a maximum pressure withstanding rating of 150 PSI. These vacuum breakers are available in brass, bronze, chrome plated brass, lead free bronze, lead free brass and polished chrome body material variants.

Frequently Asked Questions

Where should a vacuum breaker be placed?

A pressure vacuum breaker should be placed a minimum of 12 inches above all downstream outlets and pipings.

How to maintain a vacuum breaker?

Periodically inspect the vacuum breaker for signs of wear / damage and replace it if necessary.

How to install a vacuum breaker?

  • Shut the water supply off and drain the system to remove the existing water.
  • Place the vacuum breaker as per the instructions and general codes & regulations.
  • Test the vacuum breaker to make sure that it is working properly.
  • Fill up the system by turning on the water supply again.