EATON A200 Series NEMA Motor Control Interlocks
We are closed from Monday, Dec 23rd and will reopen on Monday, Jan 6th. Any orders received during this time will be processed in the New Year.

EATON A200 Series NEMA Motor Control Interlocks


Eaton A200 Series motor control interlocks are ideal for mechanically interlocking a motor starter to the load it controls. They ensure proper positioning of the motor starter to the load before the motor is started / stopped and prevent accidents or equipment damage. These mechanical interlocks are available in various sizes & configurations to suit different applications. They feature a compact design and are easy to install & maintain....Read more

Filter
StyleModelPrice (ex. VAT)
A
M-34-3A
€791.94
B
M33-5VH
€640.12
C
M-34-1A
€481.12
C
M-33-3B
€807.46
D
2050A11G25
€3,333.47
E
M-33-2B
€481.12
D
2050A11G75
€3,333.47
A
M34-2A
€481.12
E
M-33-1B
€481.12
A
M-35-2A
€481.12

Working Mechanism

  • The mechanical interlocks have a stationary housing with a movable latch connected to the control circuit of the motor starter.
  • After the motor starter is switched off, the latch remains in the locked position to prevent the load from opening or closing.
  • After the motor starter is switched on, the latch gets released to allow the load to open or close based on the motor rotation direction.
  • If the load is opened during the operation of the motor, the latch gets locked to stop the motor & prevent further damage to the equipment.
  • When the motor starter is switched off, the latch locks the load again to prevent the load from opening or closing.

Standards and Approvals

  • UL
  • CSA
  • NEMA

Frequently Asked Questions

How are these motor control interlocks installed?

Eaton A200 Series motor control interlocks can be easily installed by attaching them to both the motor starter & the load to be controlled. The specific installation process may vary based on the type of interlock used & the specific application requirements.

Do these Eaton A200 Series motor control interlocks require maintenance?

These mechanical interlocks require very low maintenance. However, they should be occasionally cleaned & inspected to ensure their functionality.

How do these motor control interlocks increase efficiency?

Eaton A200 Series motor control interlocks improve efficiency, reduce downtime & increase productivity by ensuring that the motor starter & the load are in the proper position before the motor is started or stopped.

We are here to help!

Looking for a part not listed here?