EATON Bussmann Series CLS Fuses


Eaton Bussmann Series CLS fuses are current-limiting fuses ideal for energy-limiting fault protection in indoor distribution systems. They offer effective control of fault magnitude & fault duration. These R-rated current limiting fuses operate quietly without any discharge, ensuring safety in the connected system. Selected models have an interrupt rating of 50kA....Read more

Filter
StyleModelPrice (ex. VAT)
A
2CLS-200
€4,333.64
B
5CLS-2R
€2,367.23
C
8CLS-30
€2,681.10
C
8CLS-60
€2,749.17
C
8CLS-70
€2,976.06
C
5CLS-9R
€4,182.37
B
5CLS-6R
€4,182.37
B
5CLS-3R
€2,367.23
B
5CLS-4R
€2,367.23
B
5CLS-5R
€3,339.10
B
5CLS-30
€2,042.03
B
5CLS-18R
€6,727.35
A
2CLS-25
€2,136.56
B
5CLS-24R
€6,727.35
C
5CLS-12R
€4,579.44
D
2CLS-390
€6,806.75
A
2CLS-6R
€4,110.53
A
2CLS-4R
€2,507.15
A
2CLS-2R
€2,136.56
A
2CLS-230
€4,435.73
A
2CLS-5R
€3,267.24
A
2CLS-3R
€2,329.42
D
2CLS-24R
€7,218.93
C
8CLS-4R
€2,605.47

Working Mechanism

  • When these Eaton Bussmann Series CLS fuses face high fault currents, their fuse element melts instantly to lose the energy in the surrounding sand.
  • The sand melts to form fulgurite, a glass-like substance and increases the arc voltage to approximately twice the system voltage, subsequently forcing the current to zero.
  • When these fuses face a low fault, the incoming current melts a solder drop on the silver fuse element.
  • The element burns back till a sufficient gap is established to interrupt the current. This process is commonly known as the M-effect.

Frequently Asked Questions

What are these Eaton Bussmann Series CLS fuses made of?

These precision-calibrated fuses have fiberglass-reinforced resin housing with copper-plated contact caps that are magneformed onto the housing for optimum strength. They are filled with high-purity silica sand & silver elements for efficient protection. A durable label is located on each fuse to provide ratings & manufacturer information.

How are these Eaton Bussmann Series CLS fuses mounted?

Eaton current limiting fuses feature standard industry mounting sizes. Their mountings have either disconnect or non-disconnect designs. All Eaton current limiting fuses & mountings are easy to install and operate. These R-rated motor starter fuses feature an integral hookeye for connecting to AMPGARD switchgear or have a standard clip-style mounting for easy installation.