EATON CH Series Surge Loadcenters


Eaton CH Series surge loadcenters are ideal for protecting sensitive devices & electronic equipment from surges or short bursts of high-voltage electrical energy. They have 24 / 32 / 42 circuit spaces for housing branch circuit breakers. These loadcenters come in 2 variants, surge-installed loadcenters that feature a factory mounted & wired surge suppressor device and surge-ready loadcenters that offer a provision for a field-installed surge suppressor....Read more

Filter
StyleModelPrice (ex. VAT)
A
CHEC32B150K
€1,159.63
B
CHEC32N225R
€350.23
C
CHSUR42N225L
€1,249.17
D
CHSUR42BPN200CH
€3,455.97
D
CHSUR42B200L2
€1,563.57
E
CHSUR32B100K
€1,184.29
E
CHSUR32B150K
€1,572.00
F
CHSUR32BPN100CH
€2,935.18
G
CHEC32B200K
€851.87
H
CHEC32N225K
€668.99
I
CHEC24B100E
€477.24
J
CHSUR8LF
€211.48
K
CHSUR8KS
€172.72
E
CHSUR32B200K
€1,604.44
L
CHEC42L225L
€1,010.38
J
CHSUR8LS
€211.48
I
CHEC24L125E
€761.77
K
CHSUR8KF
€120.62
M
CHSUR8EF
€129.69
M
CHSUR8ES
€129.69
N
CHSUR32N225K
€1,094.78
O
CHSUR32L225K
€1,405.12
P
CHSUR24L125E
€1,355.56
P
CHSUR24B100E
€1,201.93
F
CHSUR32B200L
€2,271.33
Q
CHEC42N225LRNSP
€750.07
R
CHEC42N225L
€812.79
S
CHEC32N225KRNSP
€552.66
T
CHEC42B200L
€1,105.36
I
CHEC32B100K
€605.54
C
CHSUR42L225L2
€1,603.32

Features

  • Eaton CH Series surge loadcenters feature NEMA 1 enclosures with a top or bottom feed for easy wiring & installation in indoor applications.
  • Surge-installed loadcenters offer factory-installed surge protection & a 2-pole circuit breaker for saving time & labour. They are generally more effective due to their reduced lead length.
  • Surge ready loadcenters allow mounting of CHSPT2ULTRA surge protector.
  • Aluminium bus in these loadcenters provide good electrical conductivity & heat dissipation.
  • A modified deadfront / knockout in the cover allows easy viewing of the indicating lights on the surge suppressors.

Compatible Accessories

  • Eaton CHSPT2ULTRA Surge Protective Device: This device is installed in surge-ready CH Series loadcenters for preventing damages due to surges.
  • Loadcenter Covers: These covers install over these loadcenters for preventing accidental operation or damage.

Standards and Approvals

  • UL 489
  • UL 1449

Frequently Asked Questions

What is the current rating of these Eaton CH Series surge loadcenters?

These Eaton CH Series surge loadcenters have current ratings ranging from 100 to 225

What is the difference between a loadcenter and a panelboard?

A loadcenter generally provides similar functionality as a panelboard in a power distribution system. However, loadcenters generally use only plug-on circuit breakers, whereas panelboards deeper than loadcenters can use both bolt-on circuit breakers & plug-on breakers.

What is the difference between the main circuit breaker and the main lug only loadcenter?

A loadcenter with a main circuit breaker design connects the incoming supply cables directly with the main circuit breaker, providing overcurrent protection for all branch circuits & a single disconnect mechanism for all loads. On the other hand, main lug only load centers are generally installed downstream of a main circuit breaker loadcenter and are typically referred to as a sub-panel. They are normally powered from a branch circuit in the main circuit breaker loadcenter.