EATON E2K Type Mining Complete Molded Case Circuit Breakers


Eaton E2K type mining complete moulded case circuit breakers prevent electrical damage to connected devices in harsh mining or industrial environments due to overloads, short circuits or ground faults. These mining circuit breakers are suitable for a wide range of monitoring and protection need...s. They are available in magnetic only or thermal-magnetic type as per your application needs.Read more

Filter
StyleModelPrice (ex. VAT)
A
E2K3400MWWU66
€11,220.33
A
E2K3225AW
€8,865.84
A
E2K3400MNWA02D11S29
€11,970.45
A
E2K3225DWU66
€10,814.01
A
E2K3250WA06U66
€11,970.45
A
E2K3350W
€9,259.61
A
E2K2400MWD09S10
€9,701.37
A
E2K2400MWWS10
€9,645.10
A
E2K2400MWD09
€7,742.76
A
E2K3225WA06U66
€11,647.46
A
E2K3400MKS54
€11,293.25
A
E2K3300WS10
€14,825.01
A
E2K3300W
€9,259.61
A
E2K3400
€9,893.06
A
E2K3400MDW
€8,865.84
A
E2K3400MJWA06T14
€11,314.08
A
E2K3400MGWU49
€10,814.01
A
E2K3400MGWU66
€10,814.01
A
E2K3400MJWA06U66
€11,991.28
A
E2K3400MKS10
€14,470.78
A
E2K3400MKWS10
€10,824.45
A
E2K3400MKWS54
€10,814.01
A
E2K3225AWU66
€10,511.89
A
E2K3400MWW
€9,259.61
A
E2K3400MNW
€9,259.61
A
E2K3400MNWU66
€11,220.33
A
E2K3400WA06
€10,180.59
A
E2K3400W
€9,259.61
A
E2K3400WU66
€11,220.33
A
E2K2400MWA06D09S10
€11,699.57
A
E2K3150W
€8,865.84
A
E2K2400MWWT14
€9,645.10
A
E2K3400MGWS10
€10,814.01
A
E2K2400MWWA06S10
€10,003.47
A
E2K2400MWW
€7,346.86
A
E2K3225DWA06U66
€11,678.74
A
E2K3250WU17
€11,220.33
A
E2K3400MAW
€8,865.84
A
E2K3400MGWA06U66
€11,522.43
A
E2K3400MDWU66
€10,814.01
A
E2K3400MFWU65
€10,814.01
A
E2K3400MNWA06
€10,180.59

Working Mechanism

  • These 3-pole circuit breakers automatically interrupt the flow of electricity and protect the equipment when a fault is detected.
  • They can be reset by switching the handle to off & then on position, once the fault has been resolved.
  • Electronic trip units in these breakers can be used for monitoring & protection of the units.

Features

  • Eaton E2K type mining complete moulded case circuit breakers have a K-frame to house the trip unit & all current-carrying devices inside their frame.
  • These circuit breakers have a built-in test kit for electronic field testing and a push-to-trip button to check the tripping function during scheduled maintenance.
  • They have a sliding handle with ON & OFF positions for easy identification of the breaker's status.
  • Selected models come with line & load end caps for easy wiring connections.

Compatible Accessories

  • Shunt Trips: These devices mechanically trip the breakers remotely by applying power (from an external source) to their shunt trip terminals.
  • Auxiliary Switches: They connect to these circuit breakers to remotely indicate whether their contacts are open or closed.
  • Alarms: They indicate the tripping of the selected breaker during remote operation.

Standards and Approvals

  • CSA
  • UL

Frequently Asked Questions

What are the interrupt ratings of these Eaton E2K type mining complete moulded case circuit breakers?

  • 65kAIC at 240VAC
  • 35kAIC at 480VAC
  • 25kAIC at 600VAC
  • 10kAIC at 250VDC

What is the difference between a thermal-magnetic type and a magnetic-only circuit breaker?

The thermal-magnetic type breaker has both thermal and magnetic elements for overload trip & inrush / instantaneous trip, respectively. The magnetic-only breakers do not have thermal protection and are mainly used for motor protection.

What is the current rating of these Eaton E2K type mining complete moulded case circuit breakers?

They have a current rating ranging from 225 to 400A & a voltage rating of 600VAC or 250VDC.

We are here to help!

Looking for a part not listed here?