EATON E2LE Type Mining Complete Molded Case Circuit Breakers


Eaton E2LE type mining complete moulded case circuit breakers prevent electrical damage to connected devices due to overloads, short circuits or ground faults. These 3-pole circuit breakers automatically interrupt the flow of electricity when a fault is detected, protecting the equipment. Users... can reset these circuit breakers after resolving the fault and can test their performance on the field in harsh mine environments. They have a moulded case design with an L-frame to house the trip unit & all current-carrying devices inside their frame.Read more

Filter
StyleModelPrice (ex. VAT)
A
E2LE34002WA06U66
€14,658.31
A
E2LE3400WA06U66
€15,043.76
A
E2LE3600MW
€13,606.07
A
E2LE3600MA02
€14,356.16
A
E2LE3600WU66
€13,908.20
A
E2LE3600MWU66
€15,575.10
A
E2LE36002WU66
€15,481.31
A
E2LE3600MWA06U66
€16,314.77
A
E2LE3400W
€11,949.59
A
E2LE3600M2W
€13,606.07
A
E2LE34002W
€11,949.59
A
E2LE3400WU66
€13,908.20
A
E2LE36002W
€6,225.88
A
E2LE3400WA06
€12,814.28
A
E2LE3400MWA06U66
€14,699.98
A
E2LE3400MW
€11,949.59
A
E2LE3400M2WU66
€13,908.20
A
E2LE34002WU66
€13,939.44
A
E2LE3600WA06U66
€16,314.77

Features

  • Eaton E2LE type mining complete moulded case circuit breakers have a sliding handle with ON & OFF positions for easy identification of the breaker's status.
  • They are available in magnetic only and thermal-magnetic types for use in specific applications.
  • These circuit breakers have a built-in test port for electronic field testing and a push-to-trip button to check the tripping function during scheduled maintenance.
  • They further feature an electronic trip with 310+ electronic LS functions to clear faults quicker than a microprocessor-initiated instantaneous trip for enhanced safety during maintenance operations.

Compatible Accessories

  • Shunt Trips: These devices mechanically trip the breakers remotely by applying power (from an external source) to their shunt trip terminals.
  • Auxiliary Switches: They connect to these circuit breakers to remotely indicate whether their contacts are open or closed.
  • Alarms: They indicate the tripping of the selected breaker during remote operation.

Standards and Approvals

  • UL
  • CSA

Frequently Asked Questions

What are the different performance ratings of these Eaton E2LE type mining complete moulded case circuit breakers?

Eaton E2LE type mining complete moulded case circuit breakers have a current rating of 400 / 600A & a voltage rating of 600VAC.

What are the interrupt ratings of these Eaton E2LE type mining complete moulded case circuit breakers?

  • 25kAIC at 600VAC
  • 65kAIC at 240VAC
  • 35kAIC at 480VAC
  • 22kAIC at 250VAC

What are the points to inspect before operating these Eaton E2LE type mining complete moulded case circuit breakers?

  • Remove the dust, dirt, grease, moisture or foreign contaminants from the unit.
  • Check that the unit's switch is free to move by switching the unit ON & OFF several times.
  • Inspect the unit for any cracks, chipping or discolouration. Tighten the terminals & connectors. Check the mounting hardware.
  • Remove any safety hazards near the installed area.

We are here to help!

Looking for a part not listed here?