EATON FD Series Complete Molded Case Circuit Breakers, F Frame

EATON FD Series Complete Molded Case Circuit Breakers, F Frame


Eaton Series C molded case circuit breakers reduce risks of damage by fault currents and fatal electrical shocks.

Filter
StyleModelAmpsNumber Of PolesVoltagePrice (ex. VAT)
A
FD3150L
---€3,796.51
B
FD1010
---€380.93
A
FD3025L
---€1,519.77
A
FD3020LM04
----
RFQ
C
FD1050L
---€460.85
D
FD4060
---€2,102.72
D
FD4030L
----
RFQ
B
FD1050
---€456.11
E
FD2070V
---€1,262.45
F
FD1030BP10
----
RFQ
A
FD3150LA10B06
---€4,227.37
E
FD2060W01V4
---€1,445.53
C
FD1025L
---€445.42
E
FD2060S22
----
RFQ
A
FD3125LA14
---€3,927.35
A
FD3150LA02
---€3,638.84
C
FD1015LBP10
----
RFQ
G
FD3225LW02
---€5,008.22
E
FD2040L
---€1,137.46
E
FD2045
---€621.73
E
FD2035
---€621.73
E
FD2030S22
---€1,844.04
E
FD2030V
---€1,093.96
A
FD3100W02
---€1,896.58
A
FD3110VH09
---€3,684.55
A
FD3110J01
----
RFQ
A
FD3100VWH09
----
RFQ
A
FD3025VH09
----
RFQ
G
FD3225A02
----
RFQ
A
FD3100VH09
---€1,656.91
C
FD1090L
---€498.51
A
FD3050VL
---€1,347.39
A
FD3050S26
----
RFQ
A
FD3050VW
----
RFQ
A
FD3050L
---€1,502.97
A
FD3050BP10
---€1,302.66
E
FD2015L
---€1,137.46
A
FD3040VL
----
RFQ
C
FD1150LM01
---€1,099.35
A
FD3040V
---€1,283.23
B
FD1150B15
----
RFQ
A
FD3045LM04
----
RFQ
A
FD3040LJ01
----
RFQ
H
FD3030H08
---€1,414.00
C
FD1125L
---€1,138.58
B
FD1110
----
RFQ
B
FD1090
----
RFQ
A
FD3040H08
---€1,455.80
B
FD1080
---€496.20
B
FD1045
---€443.90
A
FD3035BP10
----
RFQ
B
FD1035
---€487.97
H
FD3030J01F01H08
---€1,976.39
H
FD3030VH09
---€1,407.07
H
FD3030V
---€1,410.63
H
FD3030H01
----
RFQ
A
FD3110BP10
---€3,225.99
A
FD3100VL
----
RFQ
A
FD3050VH09
----
RFQ
D
FD4030E
---€2,212.52
A
FD3150LA10S22
----
RFQ

Working Mechanism

  • Eaton molded case circuit breakers are equipped with fixed thermal and fixed magnetic trips.
  • The thermal trip comprises a bi-metallic strip that gets heated when an overcurrent passes through the conductors, causing the contacts to open and interrupt the current flow.
  • The magnetic trip, on the other hand, has an electromagnetic component that detects the presence of a short circuit.
  • As the current rises abruptly, a magnetic field is created that causes the displacement in the tripping coil.
  • This opens the contact again and stops the current flow, preventing any further damage to the equipment.

Features

  • These circuit breakers feature a non-interchangeable, thermal-magnetic trip that avoids nuisance tripping on mild overloads while reacting instantly when exposed to faulty currents, thus providing maximum protection.
  • They feature a contact design that offers high-speed blow-open action, resulting in superior performance and eliminating the risk of potential hazards.
  • These FD Series complete MCCBs come with an enhanced, easy-to-use interface, allowing the operator to view and make adjustments to the trip settings.
  • They are integrated with load-side terminals for easy installation with panelboards and load centres.

Standards and Approvals

  • UL

Frequently Asked Questions

How to maintain the frame of these molded case circuit breakers?

  • Inspect the frame regularly for any signs of damage or wear like cracks, chips or corrosion.
  • Use a soft brush or cloth to remove any dirt, dust or debris from the frame.
  • Always lubricate moving parts of the frame including hinges or latches to ensure smooth operation.

What is the function of molded cases?

Molded cases hold current-carrying components, trip devices and mechanisms integrated into one unit.

We are here to help!

Looking for a part not listed here?