Eaton FDCE Series electronic MCCBs are used in data centres, healthcare facilities, manufacturing plants, hotels and shopping centres to protect electrical circuits from overloads, short circuits and faults by interrupting the flow of electricity.

Filter
StyleModelPrice (ex. VAT)
A
FDCE308035
€6,392.99
A
FDCE308036W
-
RFQ
A
FDCE316032L
€6,823.81
A
FDCE316036
€8,123.93
A
FDCE316036ZGL
€8,623.99
A
FDCE308032ZGW
-
RFQ
A
FDCE316036ZGW
€8,366.29
A
FDCE322536ZGW
-
RFQ
A
FDCE308036ZG
€6,862.28
B
FDCE316036A31B02
€8,939.42
A
FDCE308036
€6,496.85
A
FDCE316035W
€7,196.91
B
FDCE322536A31B02
-
RFQ
A
FDCE308032ZG
€6,223.76
A
FDCE322535W
€7,196.91
A
FDCE316036L
-
RFQ
A
FDCE322533
€6,262.21
A
FDCE322536L
€8,247.02
A
FDCE308032W
-
RFQ
B
FDCE308036A31B02
€7,308.48
A
FDCE322532ZG
€7,066.14
A
FDCE322535L
-
RFQ
A
FDCE308035L
€6,400.69
A
FDCE322532ZGL
€7,196.91
A
FDCE316032
€6,689.17
A
FDCE322535
-
RFQ
A
FDCE316032ZGW
€6,939.20
A
FDCE308036L
€6,504.54
A
FDCE316035L
€7,454.65
A
FDCE308032
€5,846.78
A
FDCE316036ZG
€8,500.91
A
FDCE322532W
€6,566.08
A
FDCE322532
-
RFQ
A
FDCE308036ZGL
€6,877.67
A
FDCE316036W
€7,993.16
A
FDCE322532ZGW
-
RFQ
A
FDCE322536ZG
€8,500.91
A
FDCE316035
€7,331.56
A
FDCE322532L
€6,823.81
A
FDCE308032L
€5,850.63
A
FDCE316032ZG
€7,066.14
A
FDCE316032ZGL
€7,196.91
A
FDCE308033
€5,746.76
A
FDCE308036ZGW
€6,854.58
A
FDCE316033
-
RFQ
A
FDCE322536W
€7,993.16
A
FDCE308035W
€6,381.45
A
FDCE322536ZGL
€8,623.99
A
FDCE308032ZGL
€6,227.61
A
FDCE316032W
€6,566.08
A
FDCE322536
€8,123.93

Working Mechanism

  • The electronic LSG trip unit continuously monitors the current passing through the circuit breaker.
  • If the current exceeds the preset long-time, short-time, instantaneous or ground fault pickup thresholds, the trip unit will trip the circuit breaker.
  • Once tripped, the trip unit provides diagnostic information about the fault detected and the magnitude of the current.

Features

  • These circuit breakers feature ground fault protection to prevent short circuits.
  • They offer zone-selective interlocking and communication capabilities for enhanced system monitoring & management.
  • These MCCBs come with an electronic LSG trip for advanced accuracy and low maintenance cost.

Standards and Approvals

  • UL
  • HACR

Frequently Asked Questions

How to install these MCCBs?

  • Mount the MCCB onto the mounting plate or panel.
  • Connect the cables to the MCCB terminals.
  • Set the trip settings on the MCCB.
  • Test the MCCB for proper operation.
  • Label the MCCB with the appropriate information.

How do I maintain these MCCBs?

  • Conduct periodic visual inspections of the MCCB for any signs of damage, wear or overheating.
  • Keep the MCCB and surrounding area clean and free from dust, debris or moisture.
  • Check the tightness of the cable connections and terminal screws to ensure they are properly secured.
  • Apply lubricant to the moving parts of the MCCB and calibrate the MCCB's trip settings to ensure they are accurate and provide the necessary protection.
  • Test the MCCB regularly to verify proper operation and to detect any faults or issues.
  • Replace any worn or damaged parts, including the MCCB itself, if necessary.