EATON GD Series Complete Molded Case Circuit Breakers, G Frame


Eaton GD Series moulded case circuit breakers reduce risks of damage by fault currents and fatal electrical shocks.

Filter
StyleModelAic RatingAmpsNumber Of PolesPrice (ex. VAT)
A
GD3030DVB3
---€2,272.54
B
GD3015DV
---€1,580.98
C
GD2015DVB3
---€1,588.25
C
GD2020D
---€896.68
C
GD2025V
---€896.68
C
GD2020DA3
---€1,802.44
B
GD3015A3
---€2,486.73
B
GD3015DB3
---€2,348.79
B
GD3015DA3
---€2,459.51
B
GD3015S1
---€3,368.89
C
GD2025D
---€896.68
D
GD3020A3
---€2,412.31
B
GD3015DVA6
---€3,082.10
D
GD3020A3S7
---€4,145.77
D
GD3020DS1
---€3,439.68
C
GD2015DV
---€896.68
C
GD2020A3
---€1,802.44
C
GD2025DA3
---€1,802.44
C
GD2015DVA6
---€2,277.99
C
GD2015D
---€896.68
C
GD2030C
---€896.68
D
GD3020
---€588.06
C
GD2050DV
---€1,580.98
C
GD2050DA3
---€1,802.44
A
GD3030DA3
---€2,459.51
B
GD3015CA3
---€2,459.51
B
GD3015S114
---€4,209.30
D
GD3020C
---€1,580.98
D
GD3020CA3
---€2,459.51
E
GD3090S1
---€3,882.56
C
GD2015DA3
---€1,802.44
F
GD3090D1S3
---€3,898.91
G
GD3080S4
---€3,882.56
H
GD3100A3
---€2,880.61
H
GD3100DA3
---€2,893.33
H
GD3100C
---€1,938.56
H
GD3100S1
---€3,882.56
C
GD2015DB3
---€1,802.44
C
GD2015A3
---€1,802.44
C
GD2030DA3
---€1,802.44
C
GD2035DA3
---€1,802.44
B
GD3015A3S7
---€4,062.28
C
GD2030D
---€896.68
G
GD3080DA3
---€2,893.33
G
GD3080S1
---€3,882.56
G
GD3080S3
---€3,882.56
E
GD3090DS3
---€3,898.91
C
GD2030A3
---€1,802.44
C
GD2025DV
---€896.68
C
GD2025
---€896.68
C
GD2035A3
---€1,802.44
A
GD3030DB3
---€2,459.51
C
GD2045C
---€896.68
C
GD2050A3
---€1,802.44
C
GD2035
---€896.68
C
GD2045
---€423.42
B
GD3015B3
---€2,412.31
B
GD3015A6
---€2,486.73
B
GD3015DA3S114
---€4,133.07
B
GD3015D
---€1,580.98
A
GD3030VFF01
---€3,986.03

Working Mechanism

  • Eaton GD Series moulded case circuit breakers feature fixed thermal and fixed magnetic trips to protect against faulty currents:

Fixed Thermal Trips

  • The thermal trip consists of a bimetallic strip which gets heated and bends when an overcurrent passes through the conductors, which opens the contacts and interrupts the current flow.

Fixed Magnetic Trips

  • The magnetic trip has an electromagnetic component that detects the presence of short circuits in a circuit.
  • As the current rises, a magnetic field is generated that trips the breaker and causes the contacts to open and stop the current flow.

Features

  • These units feature a fixed thermal and fixed magnetic trip unit to avoid nuisance tripping in mild current fluctuation but are highly sensitive to heavy inrush current, thus producing both instantaneous and time-delayed current limiting protection.
  • They have a compact, space-saving design that provides installation in tight spaces and allows for high-speed blow-open action, resulting in superior performance.
  • They are integrated with line and load side terminals for easy installation with panelboards and load centres.
  • These MCCBs also include a toggle and a mechanical latching mechanism that ensures the circuit breaker remains in the tripped position until it is manually reset.

Standards and Approvals

  • UL

Frequently Asked Questions

What is the advantage of moulded cases?

Moulded cases hold current-carrying components, trip devices and mechanisms integrated into one unit.

What is the purpose of a G-frame?

A G-frame is a modular design that provides a versatile and flexible platform to accommodate low-voltage circuit breakers. They also protect electrical systems from damage caused by overloads and short circuits, as well as mechanical stress.

What is the purpose of a toggle?

These circuit breakers come with an integrated over-centre toggle for visual indication of tripped status.

We are here to help!

Looking for a part not listed here?