EATON xEffect Series FRCmM-NA Residual Current Circuit Breakers


Eaton xEffect FRCmM-NA residual current circuit breakers (RCCBs) are ideal for sensing and disconnecting any low voltage (uneven current) circuit whenever a fault occurs. They are used in offices, industrial layouts and low-voltage applications.

Filter
StyleModelPrice (ex. VAT)
A
167123
€1,316.45
A
167116
€1,316.45
A
167118
€1,316.45
B
167704
€2,442.10
B
167705
€2,256.10
B
167707
€2,256.10
B
167702
€2,442.10
B
167106
€2,442.10
C
167109
€2,256.10
B
167112
€2,442.10
B
167111
€2,442.10
A
167113
€1,130.45
D
167108
€2,256.10
E
167121
€1,130.45
A
167122
€1,316.45
F
167120
€1,130.45
A
167124
€1,316.45
G
167694
€1,130.45
B
167125
€2,256.10
H
167107
€2,256.10
I
167103
€2,256.10
J
167119
€1,130.45
B
167703
€2,442.10
A
167698
€1,316.45
B
167699
€2,256.10
K
167693
€1,130.45
L
167695
€1,130.45
A
167696
€1,316.45
B
167701
€2,256.10
A
167697
€1,316.45
M
167102
€2,256.10
B
167104
€2,442.10
B
167110
€2,442.10
A
167114
€1,130.45
N
167115
€1,130.45
A
167117
€1,316.45
B
167709
€2,442.10
B
167700
€2,256.10
B
167708
€2,442.10
B
167706
€2,256.10
B
167710
€2,442.10

Working Mechanism

  • During an earth fault, the residual current circuit breaker continuously detects and contrasts any differences in the current between the live and neutral wires (residual current value).
  • The residual current circuit breaker will trip if there is even a slight difference in the numbers, cutting off the circuit.

Features

  • Eaton xEffect FRCmM-NA RCCBs feature Type A and Type G/A capable of sensing residual pulsating DC offering surge current-proof of 250A and 3kA respectively.
  • They come with a unique test button 'T' to automatically test the function of residual current circuit breakers (RCCB) themselves.
  • These RCCBs devices further feature independent line voltage tripping and operation temperature range of -25 to 40 degrees C.
  • They offer delayed tripping suitable with conventional fluorescent tubes, irrespective of whether electronic ballast is present or not.
  • These circuit breakers provide a tripping indicator and a contact position indicator for additional safety.

Standards and Approvals

  • IEC
  • EN 61008
  • UL

Frequently Asked Questions

What is the rated short circuit capacity of Eaton xEffect FRCmM-NA RCCBs?

5kA (according to CSA)

What is the rated tripping current of these residual current breakers?

30 / 300mA

How do we connect an FRCmM-NA residual current device?

  • RCCB is connected parallel to the miniature circuit breaker (MCB) into the distribution boards.
  • The phase is connected in parallel with the MCB and the neutral connection is done with neutral lines.