EATON xEffect Series FRCmM-NA Residual Current Circuit Breakers
We are closed from Monday, Dec 23rd and will reopen on Monday, Jan 6th. Any orders received during this time will be processed in the New Year.

EATON xEffect Series FRCmM-NA Residual Current Circuit Breakers


Eaton xEffect FRCmM-NA residual current circuit breakers (RCCBs) are ideal for sensing and disconnecting any low voltage (uneven current) circuit whenever a fault occurs. They are used in offices, industrial layouts and low-voltage applications.

Filter
StyleModelPrice (ex. VAT)
A
167111
€2,436.84
A
167106
€2,850.64
B
167118
€1,315.22
C
167120
€1,130.84
A
167699
€2,252.46
A
167701
€2,252.46
A
167704
€2,436.84
D
167694
€1,243.12
A
167708
€2,436.84
A
167112
€2,436.84
E
167102
€2,330.52
F
167103
€2,252.46
B
167116
€1,315.22
B
167113
€1,243.12
B
167122
€1,315.22
A
167125
€2,634.95
B
167696
€1,315.22
A
167703
€2,436.84
A
167706
€2,252.46
G
167115
€1,243.12
A
167705
€2,252.46
A
167104
-
RFQ
H
167119
€1,325.27
I
167695
€1,130.84
A
167702
€2,442.10
J
167109
€2,252.46
B
167123
€1,315.22
K
167121
€1,243.12
A
167700
€2,252.46
B
167114
€1,199.62
B
167698
€1,315.22
B
167697
€1,315.22
A
167709
€2,436.84
A
167710
€2,436.84
A
167707
€2,252.46
A
167110
€2,678.79
B
167117
€1,315.22
L
167108
€2,252.46
B
167124
€1,315.22
M
167693
€1,606.70
N
167107
€2,186.87

Working Mechanism

  • During an earth fault, the residual current circuit breaker continuously detects and contrasts any differences in the current between the live and neutral wires (residual current value).
  • The residual current circuit breaker will trip if there is even a slight difference in the numbers, cutting off the circuit.

Features

  • Eaton xEffect FRCmM-NA RCCBs feature Type A and Type G/A capable of sensing residual pulsating DC offering surge current-proof of 250A and 3kA respectively.
  • They come with a unique test button 'T' to automatically test the function of residual current circuit breakers (RCCB) themselves.
  • These RCCBs devices further feature independent line voltage tripping and operation temperature range of -25 to 40 degrees C.
  • They offer delayed tripping suitable with conventional fluorescent tubes, irrespective of whether electronic ballast is present or not.
  • These circuit breakers provide a tripping indicator and a contact position indicator for additional safety.

Standards and Approvals

  • IEC
  • EN 61008
  • UL

Frequently Asked Questions

What is the rated short circuit capacity of Eaton xEffect FRCmM-NA RCCBs?

5kA (according to CSA)

What is the rated tripping current of these residual current breakers?

30 / 300mA

How do we connect an FRCmM-NA residual current device?

  • RCCB is connected parallel to the miniature circuit breaker (MCB) into the distribution boards.
  • The phase is connected in parallel with the MCB and the neutral connection is done with neutral lines.