EATON xEffect Series FRCmM-NA Residual Current Circuit Breakers

EATON xEffect Series FRCmM-NA Residual Current Circuit Breakers


Eaton xEffect FRCmM-NA residual current circuit breakers (RCCBs) are ideal for sensing and disconnecting any low voltage (uneven current) circuit whenever a fault occurs. They are used in offices, industrial layouts and low-voltage applications.

Filter
StyleModelPrice (ex. VAT)
A
167112
€2,436.84
B
167113
€1,243.12
C
167121
€1,243.12
A
167125
€2,634.95
A
167702
€2,442.10
B
167122
€1,315.22
D
167108
€2,252.46
A
167703
€2,436.84
E
167694
€1,243.12
A
167705
€2,252.46
A
167110
€2,678.79
F
167103
€2,252.46
B
167117
€1,315.22
G
167119
€1,325.27
A
167699
€2,252.46
A
167710
-
RFQ
A
167104
-
RFQ
A
167706
€2,252.46
B
167118
-
RFQ
A
167106
€2,850.64
A
167709
€2,436.84
A
167704
€2,436.84
B
167114
€1,199.62
A
167111
€2,436.84
B
167123
-
RFQ
B
167116
-
RFQ
B
167697
€1,315.22
H
167102
€2,330.52
I
167109
-
RFQ
B
167124
€1,315.22
A
167701
€2,252.46
A
167708
€2,436.84
J
167107
€2,186.87
K
167120
€1,130.84
L
167695
-
RFQ
M
167115
€1,243.12
A
167700
€2,252.46
N
167693
€1,606.70
B
167698
€1,315.22
B
167696
€1,315.22
A
167707
€2,252.46

Working Mechanism

  • During an earth fault, the residual current circuit breaker continuously detects and contrasts any differences in the current between the live and neutral wires (residual current value).
  • The residual current circuit breaker will trip if there is even a slight difference in the numbers, cutting off the circuit.

Features

  • Eaton xEffect FRCmM-NA RCCBs feature Type A and Type G/A capable of sensing residual pulsating DC offering surge current-proof of 250A and 3kA respectively.
  • They come with a unique test button 'T' to automatically test the function of residual current circuit breakers (RCCB) themselves.
  • These RCCBs devices further feature independent line voltage tripping and operation temperature range of -25 to 40 degrees C.
  • They offer delayed tripping suitable with conventional fluorescent tubes, irrespective of whether electronic ballast is present or not.
  • These circuit breakers provide a tripping indicator and a contact position indicator for additional safety.

Standards and Approvals

  • IEC
  • EN 61008
  • UL

Frequently Asked Questions

What is the rated short circuit capacity of Eaton xEffect FRCmM-NA RCCBs?

5kA (according to CSA)

What is the rated tripping current of these residual current breakers?

30 / 300mA

How do we connect an FRCmM-NA residual current device?

  • RCCB is connected parallel to the miniature circuit breaker (MCB) into the distribution boards.
  • The phase is connected in parallel with the MCB and the neutral connection is done with neutral lines.

We are here to help!

Looking for a part not listed here?