General Electric IEC combination motor starters are suitable for operating polyphase induction motors while providing protection against both running and stalled overcurrents. They serve the purpose of initiating, stopping and safeguarding motors against overloads, short circuits and phase fail...ures. They are used in the manufacturing, mining, agriculture and HVAC industries.Read more

Filter
StyleModelAmps AcCoil VoltsControl TransformerHp @ 3 Phase - 230vHp @ 3 Phase - 240vHp @ 3 Phase - 460vHp @ 3 Phase - 480vNema Enclosure TypePrice (ex. VAT)
A
GE-CE0102HP
1 to 1.6120 VACNo1/31/33/43/44X€908.48
B
GE-CE0102SSPT1
1 to 1.6120 VACYes1/31/33/43/41€1,439.79
A
GE-CE0102HPT
1 to 1.6120 VACYes1/31/33/43/44X€980.22
C
GE-CE0102HP1
1 to 1.6120 VACNo1/31/33/43/41€934.72
D
GE-CE0102SSP
1 to 1.6120No1/31/33/43/44X€828.11
E
GE-CE0102HPT1
1 to 1.6120 VACYes1/31/33/43/41€1,439.78
A
GE-CE0102SSPT
1 to 1.6120 VACYes1/31/33/43/44X€1,098.71
F
GE-CE0102SSP1
1 to 1.6120 VACNo1/31/33/43/41€934.72
A
GE-CE0203SSPT
1.5 to 2.5120 VACYes1/21/2114X€1,013.52
A
GE-CE0203HPT
1.5 to 2.5120 VACYes1/21/2114X€980.22
C
GE-CE0203HP1
1.5 to 2.5120 VACNo1/21/2111€934.72
A
GE-CE0203HP
1.5 to 2.5120 VACNo1/21/2114X€906.11
B
GE-CE0203SSPT1
1.5 to 2.5120 VACYes1/21/2111€1,176.34
F
GE-CE0203SSP1
1.5 to 2.5120 VACNo1/21/2111€934.72
E
GE-CE0203HPT1
1.5 to 2.5120 VACYes1/21/2111€1,436.03
C
GE-CE0204HP1
2.5 to 4120 VACNo3/43/4221€932.27
A
GE-CE0204SSPT
2.5 to 4120 VACYes3/43/4224X€1,013.52
A
GE-CE0204HPT
2.5 to 4120 VACYes3/43/4224X€980.22
B
GE-CE0204SSPT1
2.5 to 4120 VACYes3/43/4221€1,436.03
A
GE-CE0204HP
2.5 to 4120 VACNo3/43/4224X€838.04
F
GE-CE0204SSP1
2.5 to 4120 VACNo3/43/4221€934.72
E
GE-CE0204HPT1
2.5 to 4120 VACYes3/43/4221€1,439.78
A
GE-CE0406SSPT
4 to 6.3120 VACYes1.51.5334X€1,011.19
C
GE-CE0406HP1
4 to 6.3120 VACNo1.51.5331€934.72
F
GE-CE0406SSP1
4 to 6.3120 VACNo1.51.5331€934.72
A
GE-CE0406HPT
4 to 6.3120 VACYes1.51.5334X€980.22
A
GE-CE0406HP
4 to 6.3120 VACNo1.51.5334X€836.05
B
GE-CE0406SSPT1
4 to 6.3120 VACYes1.51.5331€1,436.03
E
GE-CE0406HPT1
4 to 6.3120 VACYes1.51.5331€1,439.78
E
GE-CE0610HPT1
6.3 to 10120 VACYes33551€1,439.78
A
GE-CE0610HPT
6.3 to 10120 VACYes33554X€980.22
A
GE-CE0610HP
6.3 to 10120 VACNo33554X€906.11
C
GE-CE0610HP1
6.3 to 10120 VACNo33551€934.72
B
GE-CE0610SSPT1
6.3 to 10120 VACYes33551€1,439.79
A
GE-CE0610SSPT
6.3 to 10120 VACYes33554X€1,013.52
F
GE-CE0610SSP1
6.3 to 10120 VACNo33551€934.72
E
GE-CE0913HPT1
9 to 13120 VACYes337.57.51€1,189.82
D
GE-CE0913SSP
9 to 13120No337.57.54X€854.94
A
GE-CE0913HP
9 to 13120 VACNo337.57.54X€772.46
A
GE-CE0913SSPT
9 to 13120 VACYes337.57.54X€837.62
F
GE-CE0913SSP1
9 to 13120 VACNo337.57.51€878.20
A
GE-CE0913HPT
9 to 13120 VACYes337.57.54X€977.95
C
GE-CE0913HP1
9 to 13120 VACNo337.57.51€847.91
B
GE-CE0913SSPT1
9 to 13120 VACYes337.57.51€1,075.41
A
GE-CE1116HPT
11 to 16120 VACYes5510104X€1,097.64
A
GE-CE1116HP
11 to 16120 VACNo5510104X€878.18
D
GE-CE1116SSPT
11 to 16120 VACNo5510104X€1,097.64
D
GE-CE1116SSP
11 to 16120No5510104X€1,002.88
A
GE-CE1420HP
14 to 20120 VACNo5510104X€810.10
D
GE-CE1420SSPT
14 to 20120 VACNo5510104X€1,097.64
D
GE-CE1420SSP
14 to 20120No5510104X€1,002.88
A
GE-CE1420HPT
14 to 20120 VACYes5510104X€1,189.92
A
GE-CE1925HPT
19 to 25120 VACYes7.57.515154X€1,260.37
A
GE-CE1925HP
19 to 25120 VACNo7.57.515154X€878.12
D
GE-CE1925SSP
19 to 25120No7.57.515154X€1,016.47
D
GE-CE1925SSPT
19 to 25120 VACYes7.57.515154X€1,097.64
D
GE-CE2432SSPT
24 to 32120 VACNo101020204X€1,195.34
A
GE-CE2432HP
24 to 32120 VACNo101020204X€878.20
D
GE-CE2432SSP
24 to 32120No101020204X€1,021.57
A
GE-CE2432HPT
24 to 32120 VACYes101020204X€1,097.64

Working Mechanism

  • When the start button is pressed, it sends a signal to the contactor coil, which is an electromagnetic switch.
  • The contactor coil becomes energised and generates a magnetic field, causing the contactor contacts to close. These contacts connect the motor to the power supply.
  • With the contacts closed, electrical power flows to the motor, initiating its rotation.

Features

  • They feature a robust enclosure with a NEMA rating, ensuring protection against environmental factors such as dust, moisture and corrosive substances.
  • These IEC combination starters have operator selector switches, allowing users to easily choose between different operational modes, such as Hand, Off or Auto, providing control and flexibility.
  • They are equipped with pilot lights incorporating pilot lights that indicate the equipment's operational status and simplify troubleshooting by quickly identifying the equipment's condition.

Standards and Approvals

  • UL
  • CSA

Frequently Asked Questions

What does IEC stand for?

The IEC stands for International Electrotechnical Commission. It establishes the global standard for electric motors, providing a framework that is similar to other international standards organisations.

What is the difference between a combination starter and a motor starter?

Combination motor starters offer an efficient solution by consolidating both the motor starter and electrical protection devices within a single enclosure. These starters are specifically designed to ensure user safety while enabling the convenient starting and stopping of a motor using an electromechanical switch.

What maintenance tasks are necessary to prolong the lifespan of General Electric IEC combination starters?

Regularly inspect and tighten connections, replace worn components and perform thermal inspections to identify potential issues proactively.

How can I determine the appropriate size of an IEC motor starter for my motor?

While choosing make sure that the specifications such as motor's full load current (FLC), starting current and voltage. Consult the manufacturer's sizing charts and recommendations for accurate selection.