<span Class='notranslate'>Dwyer Instruments </span> 616kd-04 | 24z021 | Differential Pressure Transmitter, 1/8 Inch Hose Barb, 0 To 10 Inch Wc, 4 To 20ma Dc Output
We are closed from Monday, Dec 23rd and will reopen on Monday, Jan 6th. Any orders received during this time will be processed in the New Year.
Flat Shipping
Flat Shipping at

DWYER INSTRUMENTS 616KD-04 Differential Pressure Transmitter, 1/8 Inch Hose Barb, 0 to 10 Inch WC, 4 to 20mA DC Output | AB8ACR 24Z021

DWYER INSTRUMENTS 616KD-04 Differential Pressure Transmitter, 1/8 Inch Hose Barb, 0 to 10 Inch WC, 4 to 20mA DC Output

Item: AB8ACR Model: 616KD-04Cross Ref: 24Z021
In Stock

Get it by Tuesday, Dec 31

Flat Shipping at € + TVA € flat shipping is applicable on orders with an aggregate weight less than 10kg. Orders exceeding 10kg will be charged default shipping rates.

€120.73 /unit
Add To Cart
Request a Quote

Payment Options Available

Product Specifications:

ItemPressure Transmitter
Accuracy-/+ 2% Full Scale
Connection Size1/8", 3/16"
Connection TypeBarbed
Electrical ConnectionScrew Terminal
Enclosure RatingNema 1
Loop Resistance0 to 1250 Ohm for DC, 0 to1200 Ohm for AC
Mounting OrientationVertical
Output4 to 20 mA
Output Accuracy-/+2% Full Scale
Output Current4 to 20 mA
Power Required16 to 35V DC
Pressure Range0 to 10" wc
Temp. Range0 Deg. to 140 Deg. F

Shipping Info:

Ship weight (kg) 0.2025
Ship height (cm)2.79
Ship length (cm)12.7
Ship width (cm)8.13
HS code9026204000
Country of OriginUS

Product Details:

The 616KD Series Differential Pressure Transmitters with One-Touch® technology are cost-effective, compact transmitters that reduce up front costs as well as expenses over the life of the product. The transmitter not only alleviates cumbersome turn pots typically found in most transmitters, but eliminate entirely the need to span the instrument during calibration. With a single digital push button, both ZERO AND SPAN are calibrated properly, nothing else is required. No additional reference pressure sources and separate calibration devices are necessary; no need to remove from service and send to a lab. All that is required of the installer or user is to let the unit sit at zero reference pressure, then push a button. That is it! The transmitter is now ready for operation. Time savings are enormous over the life of the product compared to traditional transmitters which require time to annually remove the product from service plus the additional time to actually perform a complete full-span calibration.

Explore Products

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

DWYER INSTRUMENTS 616KD-04 Differential Pressure Transmitter, 1/8 Inch Hose Barb, 0 to 10 Inch WC, 4 to 20mA DC Output
€120.73 /unit