ELOBAU 117614E1-10 Safety Sensor, With Built In Relay | CL7NCD

ELOBAU 117614E1-10 Safety Sensor, With Built In Relay

Item: CL7NCD Model: 117614E1-10
Limited Availability
Request a Quote

Payment Options Available

Product Specifications:

ItemSensor
Actuation Frequency18000/1 h
Actuation TypeFront
Air Pressure860 to 1060 hPa
Assured Switch Off Distance21 mm
Assured Switching Distance3 mm
Cable ColorSilver Grey
Cable Length1 m
Cable MaterialTPE
Cannot Be Mounted FlushNo
Continuous Shock Resistance10 g/ 16 ms
Current Consumption100 mA
Degree Of Pollution2
Delta Tmax0.5 Deg. C/min.
Edm/start InputNo
Free Zone25 mm
Fuse Control Output3A
Fuse Operating Current0.5A
Fuse Safety Output3A
Housing ColorSilver
Housing DesignRectangular
Housing MaterialPBT
Ip RatingIp67
Led DisplaySingle Coloured
Max. Cable Temp. Range, Fixed Installation55 Deg. C
Max. Cable Temp. Range, Moving55 Deg. C
Max. No. Operating Cycles At 0.5a Switching Current (ohmic Load)1000000
Max. No. Operating Cycles At 2.5a Switching Current (ohmic Load)230000
Max. Operating Speed0.1 m/min.
Max. Operating Temp.55 Deg. C
Max. Operating Voltage253V AC
Max. Storage Temp.55 Deg. C
Max. Switching Current At Control Output3A
Max. Switching Power At Control Output750VA, 90W
Max. Switching Power At Safety Output750VA, 90W
Max. Switching Voltage At Control Output250V AC/ 30V DC
Max. Switching Voltage At Safety Output250V AC/ 30V DC
Min. Cable Temp. Range, Moving-25 Deg.
Min. Cable Temperature Range, Fixed Installation-25 Deg. C
Min. Operating Temp.-25 Deg. C
Min. Operating Voltage207V AC
Min. Storage Temp.-25 Deg. C
Min. Switching Current At Control Output0.01A, 3A
Min. Switching Current At Safety Output0.1A
Min. Switching Power At Control Output0.12W
Min. Switching Power At Safety Output0.5W
Min. Switching Voltage At Control Output12V AC/DC
Min. Switching Voltage At Safety Output5V DC
Minimum Installation Distance (between Two Sensors)50 mm
Minimum Switching Distance0.5 mm
Mounting TypeScrew
Number Of Relay Control Output1
Number Of Relay Safety Output1
Number Of Strands5
OvervoltageCategory III
Power Consumption23VA
Protection ClassClass III
Readiness Delay350 ms
Relative Humidity5% to 85 %
Shock Resistance30 g/ 11 ms
Size120 mm x 40 mm x 40 mm
Switching PrincipleMagnetic
TechnologyReed
Utilization Category15-AC/-13-DC
Vibration Resistance10 Hz to 55 Hz
Wire Cross Section0.75 Sq. mm

Product Variants

ProductModelActuation FrequencyActuation TypeAssured Switch Off DistanceAssured Switching DistanceCable LengthCable MaterialCable SizeCannot Be Mounted FlushPrice
ELOBAU 171V62AY Safety Sensor, Magnetically Actuated, N.O./N.O., Built In Connector, M12 Size | CL7MND 171V62AY-Front16 mm4 mm---Yes-
RFQ
ELOBAU 114270A0D Safety Sensor, Magnetically Actuated, N.O./N.C, Built In Connector, M8 Size | CL7MNX 114270A0D-Front19 mm7 mm-----
RFQ
ELOBAU 171V62VY Safety Sensor, Magnetically Actuated, N.O./N.O., Built In Connector, M12 Size | CL7MPA 171V62VY-Front16 mm4 mm---Yes-
RFQ
ELOBAU 114270-5 Safety Sensor, Magnetically Actuated, N.O./N.C. 5m Cable | CL7MPC 114270-5-Front19 mm7 mm1 mPVC---
RFQ
ELOBAU 153V62-10 Safety Sensor, Magnetically Actuated, N.O./N.O., 10m Cable | CL7MPF 153V62-10---------
RFQ
ELOBAU 165270-5 Safety Sensor, Magnetically Actuated, N.O/N.C., 5m Cable | CL7MPH 165270-5----1 mPVC---
RFQ
ELOBAU 120272-5 Safety Sensor, Magnetically Actuated, N.O/N.C., 5m Cable | CL7MPJ 120272-5-Front22 mm4 mm1 mPVC---
RFQ

Explore Products

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

ELOBAU 117614E1-10 Safety Sensor, With Built In Relay