Product Specifications:

ItemClosed System Oiler
Bowl MaterialGlass
Capacity4 oz.
Collar MaterialZinc
Connection1/4" NPT
FunctionMaintains Constant Level Of Oil And Prevents Accidental Overfilling
Height7 1/16" to 7 13/16"
Product Datasheettrico-30203.pdf
Width2 11/16"

Shipping Info:

Ship weight (kg) 0.765
Ship height (cm)17.93
Ship length (cm)5.23
Ship width (cm)5.23
HS code8413919520
Country of OriginUS

Standards and Approvals:

  • ISO 9001:2015
  • ISO / IEC 17025:2017
  • ASTM
  • API

Frequently Asked Questions:

Q. How are oiler closed system installed?

A.

  • Before installing, shaft rotation direction must be determined.
  • Install the oiler on the side of the equipment facing the direction of shaft rotation to prevent misfeeding of the oiler.
  • Loosen set screw and remove reservoir.
  • Tighten supplied plug in the side or bottom fluid port.
  • Apply pipe thread sealant to both ends of an NPT male nipple (not included) and tighten it in the remaining fluid port & bearing housing.
  • The closed system should be parallel to the bearing housing in a vertical position.
  • Apply pipe thread sealant to a male connector (not included) and tighten it into the vent port. Repeat the same with the second male connector.
  • Connect a section of copper or nylon tubing to the NPT connectors to serve as the vent line.
  • With the Allen key, adjust the collar to the desired fluid level.
  • Fill the bearing chamber through the main body until it reaches just below the optimum fluid level visible in the sight gauge.
  • Use the reservoir to feed oil to the proper level.
  • Place thumb over reservoir spout, invert and insert the spout into the main body until upper casting bottoms out on the collar.
  • Secure set screws on upper casting and start up the machine.