Flow Switches

Filter

<p>Flow switches detect fluid flow in hydraulic systems and prevent leaks. They are used in pumps in the water treatment, oil & gas and chemical industries.</p>
IFM -

Flow Switch, 3/4 NPT Connection Size, 26.4, 363 PSI Max. Pressure, 24 VDC, DC/PNP, 100mA

ModelItemPrice (ex. VAT)
SBN333CR4LMQ€524.87
JOHNSON CONTROLS -

Air Flow Switch, 2-1/8 Inch x 6-7/8 Inch Paddle Size, 16.0/8.0

ModelItemPrice (ex. VAT)
F262KDH-01CCR6AJW€309.42
SIEMENS -

Liquid Flow Switch, 1 MNPT Connection Size, 10, 160 psi Max. Pressure, 24V DC

ModelItemPrice (ex. VAT)
QVE1900UCU2UTZ€213.99
DWYER INSTRUMENTS -

Level Switch Brass Body Spdt

ModelItemPrice (ex. VAT)
L6EPB-B-S-3-BCP4LMY€663.49
IFM -

Flow Switch, 1 NPT Connection Size, 26.4, 363 PSI Max. Pressure, 24 VDC, DC/PNP, 10mA

ModelItemPrice (ex. VAT)
SBN346CR4LMP€554.87
DWYER INSTRUMENTS -

Thermal Dispersion Flow Switch

ModelItemPrice (ex. VAT)
TDS112CP4LMX€847.92
DAYTON -

Flow Protector Booster Pump 115 V

ModelItemPrice (ex. VAT)
1DGZ7AA9HXL€539.03
WATTS -

Flow Switch, 1 Inch NPT Size

ModelItemPrice (ex. VAT)
FS-200-WCB2TZH€630.25
DAYTON -

Flow Protector Booster Pump 230 V

ModelItemPrice (ex. VAT)
1DGZ8AA9HXM€618.65
MCDONNELL & MILLER -

Switch Liquid Flow, 1 1/4 MNPT, 300 Psi

ModelItemPrice (ex. VAT)
FS7-4AD9ECV€823.88
MCDONNELL & MILLER -

Air Flow Switch, Brass, SPDT 120/240 V

ModelItemPrice (ex. VAT)
AF-1AD9EDA€455.53
DWYER INSTRUMENTS -

Liquid Flow Switch, 1/2 Inch MNPT, 1000 PSI Max. Pressure AC, SPST

ModelItemPrice (ex. VAT)
V10AH2CXN€141.67
MCDONNELL & MILLER -

Flow Switch 1 Inch SPDT

ModelItemPrice (ex. VAT)
FS4-3AH6EQJ€215.67
MCDONNELL & MILLER -

Flow Switch 1 Inch Nema

ModelItemPrice (ex. VAT)
FS8-WAH6EQK€449.30
WATTS -

Wet Location Flow Switch, 1 Inch Inlet, 250 Deg. F

ModelItemPrice (ex. VAT)
FS-204-WCC7JFQ€759.83
DWYER INSTRUMENTS -

Flow Switch Brass

ModelItemPrice (ex. VAT)
V6EPB-B-S-LFCP4LMW€620.23
HONEYWELL -

Flow Switch Kit, Single Pack

ModelItemPrice (ex. VAT)
50053268-018/UBN9YWH€212.64
See Details
HONEYWELL -

Air Flow Switch

ModelItemPrice (ex. VAT)
4074ETH/UBP2AFQ€113.86
See Details
HONEYWELL -

Flow Switch, 1 Inch NPT Size

ModelItemPrice (ex. VAT)
FS4-3/UBP3GTN€276.36
See Details
HONEYWELL -

Flow Switch, 1-1/4 Inch NPT Size

ModelItemPrice (ex. VAT)
FS7-4/UBP3GTR€645.06
See Details
BRADLEY -

Flow Switch, 1/2 Inch NPT, Brass

ModelItemPrice (ex. VAT)
S19-319B2CD4EAZ-
RFQ

Flow Switches

Flow switches are primarily designed to monitor the air, steam or liquid flow and send signals to the pump for automatic ON / OFF switching with the rise and fall of water level; ideal for regulating water cooling equipment and water treatment or hydronic heating systems. Raptor Supplies offers a wide range of these liquid flow switches from brands like Bradley, Dwyer Instruments, Mcdonnell & Miller, Dayton, Johnson Controls, Gems Sensors and Taco. Gems Sensors flow switches uses 100-micron filtration technology and are less susceptible to clogging than other high-pressure inline flow switches. These units come equipped with one-piece magnetic composite piston which actuates the sealed reed switch when displaced by the pressure difference in fluid flow, thereby activating remote alarms or indicators. They are available in brass, polypropylene and stainless steel construction with a maximum pressure rating and flow rate of 1500 psi and 2 GPM, respectively. Taco industrial flow switches feature flow sensitivity adjustment mechanism for setting a wide adjustment range to start or stop an electronically operated device when flow / no-flow condition occurs. These low-flow switches come with a highly malleable EPDM seal providing anti-hardening, cracking and leakage properties and improving the performance in high-pressure applications such as chillers, boilers, heating systems and water systems. They are available in NEMA 1 and NEMA 4 rated enclosures providing protection against the ingress of foreign contaminants and are ideal for use with 1 - 8 inch (outer diameter) pipe sizes.

Frequently Asked Questions

How can I maintain the accuracy of my flow switch over time?

  • Regularly clean the flow switch and inspect it for any signs of damage, corrosion or debris buildup.
  • Verify that the flow switch is properly aligned within the flow path to ensure accurate measurements.
  • Periodically calibrate the flow switch to verify its accuracy.
  • Take into account the properties of the fluid being monitored, such as viscosity or density, as these factors can impact the accuracy of the flow switch.
  • Be aware of the ambient conditions surrounding the flow switch. Consider protective enclosures for use in harsh environments.
  • Maintain a record of the flow switch's calibration dates, maintenance activities and any observed issues.

What is the difference between a flow switch and a pressure switch?

A flow switch measures the flow rate of media flowing through a process line, whereas a pressure switch measures the pressure within a process line, pipe or vessel.

How do I select the right flow switch for my application?

Consider factors like the type of fluid, flow rate, operating conditions (temperature or pressure) and pipe size.

Do these flow switches require regular maintenance?

These flow switches require minimal maintenance. However, periodic inspection and cleaning are necessary to ensure proper functioning.

Can I use these flow switches for both liquids and gases?

Yes, these flow switches can be used to detect the flow of both liquids and gases.

We are here to help!

Looking for a part not listed here?