HOFFMAN Spectra Cool N21 Series Narrow Indoor/Outdoor Enclosure Air Conditioners
We are closed from Monday, Dec 23rd and will reopen on Monday, Jan 6th. Any orders received during this time will be processed in the New Year.

HOFFMAN Spectra Cool N21 Series Narrow Indoor/Outdoor Enclosure Air Conditioners


Hoffman SpectraCool N21 Series narrow air conditioners offer a cool air supply when installed inside a more narrow, low-depth cabinet. These air conditioners fit on 12-inch (300-mm) deep wall & floor-mount enclosures with minimal visible fastener usage. They require 115, 230 or 460VAC power inp...ut inside their terminal block.Read more

Filter

Features

  • Hoffman SpectraCool N21 Series narrow air conditioners have an aluminium mesh filter that is cleanable & reusable to protect coils from contaminants & ensure maximum cooling performance.
  • They have a mechanical thermostat on their enclosure for easy control of temperature set points.
  • Their condenser coils are dust resistant for filterless operation in most applications.
  • The units have a NEMA-rated galvanised steel or stainless steel sheet cover for application in outdoor environments.
  • Indoor air conditioners further feature active condensate management with heater strip, power-off relay for matching door switch & other system requirements and malfunction switch as a safety standard.
  • They have a normal capacity of 2000 BTUh or 586W.
  • These air conditioners use R134a earth-friendly refrigerants.

Compatible Accessories

  • Hoffman 89206050 Remote Digital Controller: This unit allows remote monitoring & managing of SpectraCool air conditioners with a secure internet connection for increased productivity & reliability.

Standards and Approvals

  • UL/cUL
  • CE
  • EAC

Frequently Asked Questions

What is the operating temperature of these Hoffman SpectraCool N21 Series narrow air conditioners?

These air conditioners are operated at temperatures ranging from -40 degrees F (-40 degrees C) to 131 degrees F (55 degrees C).

How to install these Hoffman SpectraCool N21 Series narrow air conditioners?

  • Inspect the air conditioner & determine whether to surface or recess mount them.
  • Prepare the enclosure opening and use a gasket kit to install gaskets to the air conditioner.
  • Mount the air conditioner on the enclosure in an upright position.
  • Route the unit's drain tube without kinking or elevating it above the unit's exit point.
  • Connect the power cord to a properly grounded power supply.

How to set the temperature of the thermostat in these Hoffman SpectraCool N21 Series narrow air conditioners?

  • Remove the nylon plug from the unit's front face.
  • Use a standard screwdriver to turn the adjustment screw clockwise for cooler settings and adjust the screw counterclockwise for warmer settings.
  • Reinstall the nylon plugs on the unit.