BUSSMANN LPJ-30SP Low Peak Fuse, 30 A, 600 V | AE2GKM 4XF35

BUSSMANN LPJ-30SP Low Peak Fuse, 30 A, 600 V

Item: AE2GKM Model: LPJ-30SPCross Ref: 4XF35
In Stock : 521 Units

Get it by Friday, Nov 29

€19.31 /unit
Add To Cart
Request a Quote

Payment Options Available

Product Specifications:

ItemFuse
Ac Voltage Rating600V
Body MaterialMelamine
Body StyleCylinderical
ClassClass J
Current Rating30A
Dc Voltage Rating300V
DepthNot Applicable
Diameter13/16"
ElementDual
For Fuse Block SeriesCH30J, CH60J, J600, JM600, JM601, JM602, JM604, JM606, JP600, JT600, JTN600
Functionally Equal ToFerraz/Gould AJT, Littelfuse JTD
Fuse Amps30
Fuse Block DesignNon Rejection
Fuse Holder CodeZ
Indicating / NonindicatingNonindicating
Interrupt Rating100kA at 300V DC, 300kA at 600V AC
Length2 1/4"
Mfr. SeriesBussmann LPJ, Littelfuse JTD, Mersen AJT
Rejection / NonrejectionRejection
SpeedTime Delay
Visual IndicationNon Indicating
Voltage Rating600VAC/300VDC
WidthNot Applicable

Shipping Info:

Ship weight (kg) 0.027
Ship height (cm)2.03
Ship length (cm)5.84
Ship width (cm)2.03
HS code8536100040
Country of OriginMX

Product Details:

Bussmann LPJ-30SP Low-Peak fuse is a time delay fuse that uses long time-delay to minimise needless fuse openings due to temporary overloads and transient surges. It is used to control the timing of switching operations in a motor startup.

Features:

  • Bussmann LPJ-30SP Low-Peak fuse has two elements for both time-delay and current-limiting functions.
  • Its long time delay minimises unnecessary fuse openings due to temporary overloads andtransient surges.
  • The current limiting capability of this fuse protects downstream components from harmful thermal and magnetic effects of short-circuit currents.
  • This fuse has a melamine body to resist heat generated during resisting overcurrents.

Frequently Asked Questions:

Q. What is the interrupt rating of this Bussmann fuse?

A. It has an interrupt rating of 100kA at 300VDC and 300kA at 600VAC.

Q. How do I test a fuse to see if it's blown?

A. You can use analogue multimeters or digital multimeters to test whether the fuse has blown or not.

Q. What precautions should I take when replacing a blown fuse?

A. When replacing a blown fuse, ensure that the circuit is de-energised to prevent electric shock.

Product Variants

ProductModelBody StyleConnection TypeCurrent RatingDiameterFuse AmpsFuse Holder CodeLengthVisual IndicationPrice
BUSSMANN LPJ-3SP Low Peak Fuse, 3 A, 600 V | AE2GKC 4XF26 LPJ-3SPCylinderical-3A13/16"3Z2 1/4"Non Indicating€23.79
BUSSMANN LPJ-15SP Low Peak Fuse, 15 A, 600 V | AE2GKJ 4XF32 LPJ-15SPCylindericalFerrule End x Ferrule End15A13/16"15Z2 1/4"Non Indicating€19.31
BUSSMANN LPJ-35SP Low Peak Fuse, 35 A, 600 V | AE2GKN 4XF36 LPJ-35SPCylinderical-35A1 1/16"35AA2 3/8"Non Indicating€34.72
BUSSMANN LPJ-60SP Low Peak Fuse, 60 A, 600 V | AE2GKR 4XF39 LPJ-60SPCylindericalFerrule End x Ferrule End60A1 1/16"60AA2 3/8"Non Indicating€34.72
BUSSMANN LPJ-70SP Low Peak Fuse, 70 A, 600 V | AE2GKT 4XF40 LPJ-70SPBlade-70A1 1/8"70AB4 5/8"Non Indicating€75.59
BUSSMANN LPJ-100SP Low Peak Fuse, 100 A | AE2GKV 4XF42 LPJ-100SPBlade-100A1 1/8"100AB4 5/8"Non Indicating€85.88
BUSSMANN LPJ-12SP Low Peak Fuse, 12 A, 600 V | AE8QRX 6F365 LPJ-12SPCylindericalFerrule End x Ferrule End12A13/16"12Z2 1/4"Non Indicating€19.31

Explore Products

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 07:30 until 17:00.

BUSSMANN LPJ-30SP Low Peak Fuse, 30 A, 600 V
€19.31 /unit